No. C-1, Chuntianyuan, Ganjingzi District, Dalian City, Liaoning Province, P.R. China
✕

Full phase-out of coal boilers at 10 t/h and below, and where grate demand moves

26 Nov,2026 WhatsApp: +8615382281005 Email: sales@cnlky.com

On 4 November 2026 the website of the National Development and Reform Commission (NDRC) published the Action Plan for Implementing the Comprehensive Resource-Saving Strategy. The plan was issued jointly by five departments — the NDRC, the Ministry of Industry and Information Technology, the Ministry of Natural Resources, the Ministry of Water Resources and the National Government Offices Administration — under document number Fagai Huanzi [2026] No. 1424, with a signing date of 29 September 2026. It runs to 9 chapters and 22 measures, and in the chapter on deepening energy saving and efficiency improvement, under the item on curbing unreasonable growth in total energy consumption, it states: vigorously advance the clean substitution of coal-fired boilers and coal-fired industrial kilns, and fully phase out coal-fired boilers at 10 t/h and below.

The sentence is short, but for the grate-fired boiler supply chain it is a clear signal. The same formulation appeared in both the 2018 and the 2023 State Council documents, and the wording was not the same; the difference is not in the number but in the qualifier attached to it.

Grate surface and drive end of a chain grate (stock image)

Photo: Elmschrat, CC BY-SA 3.0, via Wikimedia Commons

1. Set the three documents side by side and the change sits in the qualifiers

  • 2018, Three-Year Action Plan for Winning the Blue Sky Defense Battle (Guofa [2018] No. 22): in the built-up areas of cities at county level and above, coal-fired boilers of 10 t/h and below, together with tea-water furnaces, commercial stoves and similar coal-burning facilities, were to be basically phased out.
  • The same document also provided that new coal-fired boilers below 35 t/h were in principle no longer to be built, and that in other areas new coal-fired boilers below 10 t/h were in principle no longer to be built.
  • 2023, Action Plan for Continuous Improvement of Air Quality (Guofa [2023] No. 24): in the built-up areas of cities at county level and above, new coal-fired boilers of 35 t/h and below were in principle no longer to be built.
  • The same document set the target that by 2025, cities not attaining the PM2.5 standard were to have basically phased out coal-fired boilers of 10 t/h and below, and key regions were to have basically phased out coal-fired boilers of 35 t/h and below.
  • 2026, Action Plan for Implementing the Comprehensive Resource-Saving Strategy (Fagai Huanzi [2026] No. 1424): fully phase out coal-fired boilers at 10 t/h and below.

Read together, the object of the phase-out has not changed; the scope of the subject has. What used to be qualified by “built-up areas”, “cities not attaining the PM2.5 standard” and “key regions” becomes an unqualified “full” phase-out, with no geographic precondition, and the supervisory wording moves from “basically phased out” to “fully phased out”. The same plan also calls for accelerating heating retrofits of coal-fired units and the associated pipe networks, retiring old and inefficient coal-fired units and boilers, and advancing in an orderly way the retirement of inefficient coal-burning facilities and equipment in agricultural, commercial and residential use. The direction is consistent: small and dispersed coal-burning equipment is being closed out, and heat supply is moving towards centralised and clean sources.

2. Which class of equipment is being phased out

10 t/h is evaporative capacity; converted at the common ratio of roughly 1 t/h to 0.7 MW, it is an industrial and heating boiler of about the 7 MW class. That tonnage band is almost entirely grate-fired: coal is fed in at the front, and drying, devolatilisation, coke combustion and burn-out all take place on the grate, with ash discharged at the discharge end. The grates fitted are mainly chain grate, with reciprocating grate and fixed grate also present.

The characteristics of this fleet are tightly clustered: small single units, scattered sites, low annual operating hours, thin operations and maintenance staffing. They are both the main destination for small grate bars, side splints and slag remover parts, and the place where “replace it when it breaks” spare-part purchasing clusters. What the phase-out targets is the boiler body and the way it burns coal, not grate firing as a technology — the same grate-fired structure burning a different fuel is still the choice of many small and medium heat users.

3. Different replacement paths leave different grates behind

“Clean substitution” is the same phrase in every case, but on the equipment side it resolves into four paths with quite different consequences for the grate supply chain:

  • District heating substitution: the small boilers are demolished and heat arrives from a district boiler house or a combined heat and power network. What remains is large-capacity chain grate, reciprocating grate and circulating fluidised bed, where the grate area per unit is large and spare-part specifications are concentrated, so demand for small-format parts falls away.
  • Conversion to moulded biomass fuel: the grate-fired structure is retained, and the grate is usually a reciprocating grate, a flake-type chain grate or a travelling grate. This is currently a comparatively steady block of demand for grates and heat-resistant spares.
  • Conversion to gas or electricity: there is no grate at all, so demand for grate bars and slag removal parts goes to zero.
  • Clean substitution of industrial kilns: some kilns still use grate firing, so grate-part demand is retained, but the requirements on material and on air distribution become finer.

The conclusion is not hard to draw: orders for new small coal-fired boilers will keep narrowing, and the centre of gravity of grate demand shifts from “supplied with a new boiler” to “supplied for the fuel conversion of the existing fleet” and “replacement of worn parts on the existing fleet”. The purchasing logic of those two blocks differs: the first looks at drawings and fuel parameters, the second at whether a specification can be matched to an old boiler model.

4. Coal to biomass is not just a fuel swap, four places on the grate have to move

When the fuel changes from coal to moulded biomass pellets or loose biomass, four places on the grate of the same boiler usually have to move, and this is the part of a retrofit project that is easily underestimated:

  • Grate area and heat load. Biomass has a lower calorific value and higher moisture than coal, so the same evaporative capacity needs a larger grate area and a lower grate heat release rate; otherwise combustion is incomplete and the carbon content of the ash rises. Whether the furnace has the space for it often decides whether the project is feasible at all.
  • Air-flow section ratio and air distribution. Biomass has high volatile content and ignites quickly, so primary air has to be adjusted zone by zone, and the grate air-flow section ratio and the windbox partitions have to follow the fuel. Leave the air distribution unchanged and the usual result is burn-through in the front section of the grate and raw fuel carried off the back.
  • Feeding and slag removal. Moulded pellets differ from coal in angle of repose and flowability, so the feeder, the layered coal hopper and the slag remover have to be matched again; biomass ash is smaller in quantity but has a low ash melting point, so slagging tends to move from the grate surface into the grate gaps and the slag discharge outlet.
  • Material and corrosion resistance. Biomass ash is high in chlorine and alkali metals, and both high-temperature and low-temperature corrosion are more pronounced than with coal, so grate bar material has to move from ordinary grey cast iron towards high-silicon or chromium-bearing heat-resistant cast iron, with the grade and heat-treatment condition fixed together with the retrofit scheme.

One further point is easily overlooked: switching to biomass does not by itself remove environmental obligations. The 2018 document already stated that biomass boilers in urban built-up areas were to undergo ultra-low emission retrofits, and retrofit projects are still held to the emission standard for air pollutants from boilers.

Biomass boiler house (stock image)

Photo: Joe Mabel, CC BY-SA 3.0, via Wikimedia Commons

5. What it means for spare-part purchasing and export markets

At home, replacement of the existing fleet means three things: orders for small-format grate parts will slowly thin out; in the spare-part lists of retrofit projects, confirming material grade and grate dimensions becomes a more important step; and old boiler models with no drawings to be found will become more common, so measuring capability catches more orders than inventory depth does.

Abroad, small and medium grate-fired boilers are still running in markets such as Vietnam and Thailand, where small coal-fired boilers and biomass conversions coexist and spare-part demand has not closed down in step. When a customer of this kind buys, the three things worth settling first are the grate pitch and effective width of the original boiler model, the material grade (and whether supply is to the drawing grade), and the ash and moisture range of the fuel after conversion. Once those three are fixed, price and lead time can be quoted with any accuracy. As a supplier we hold these three as the opening questions of every enquiry, before any commercial discussion starts.

For how wearing parts are specified and which ones fail first, see the grate spare parts list; for how material is selected against operating conditions, see the classification of mainstream grate bar materials.

References